Incoming inspection should verify that the delivered item matches the order and arrives in suitable condition. It is a controlled receiving process, not a substitute for all application testing.
Check identity and completeness
Compare the nameplate, order code, quantity and accessories with the purchase order. Verify drawing revision where specified. Record batch or serial information when available and keep it connected to the receiving record.
Check packaging and visible condition
Inspect for transit damage, missing port protection, corrosion and damaged connectors. Keep suspect items separate from approved stock. Opening protected ports unnecessarily can introduce contamination, so follow a clean inspection method.
Complete the agreed technical checks
Use the inspection plan to decide which dimensions or functions must be checked. Test equipment and personnel should be appropriate for hydraulic pressure hazards. Document discrepancies with photographs and specific requirements so the supplier can respond to evidence rather than a vague rejection.
Practical checklist
- Match complete configuration and included accessories.
- Record packaging condition and traceability information.
- Use the agreed acceptance plan for technical checks.
Discuss your application
Explore related hydraulic products, or send JIUDING your model code and application details. Include the circuit drawing and the operating conditions relevant to the checks above so the required configuration can be reviewed.